Concrete Pumps Sample Clauses Related Information

Hazard Analysis - FEATURE: CONCRETE, CAST-IN-PLACE

Working with Concrete Pump Truck Dermal irritant/eye irritant Review concrete MSDS and avoid contact with wet concrete or dry. Provide job specific training for concrete hazards prior to it's use. Have MSDS available in case of an emergency. Eyewash station shall be located in the immediate work area. Inform employee of the location of the station.

Loss of Air Content in Pumped Concrete — What, why, & how

1 American Concrete Pumping Association Certification Program for Concrete Pump Operators OBJECTIVES To raise the professional standards of the concrete pumping industry in general, and of concrete pump operators, in particular To improve the safety awareness and practice of concrete pump operators To encourage continuing education of concrete pump operators

Scope of Work in Construction Contracts - Building Advisor

A construction contract is broadly divided into two main sections: the Scope of Work and the General Conditions. The Scope of Work describes the work to be done, by whom, and when. The General Conditions is basically everything else in the contract, the so-called "fine print," defining the legal rights and responsibilities of the parties

Concrete Construction | ConcreteConstruction.net

concrete supplier, testing and inspection agency, specifier, and even the owner. In the simplest situation the ready mixed con-crete producer will incorporate a reference to C 94 in the delivery ticket for concrete supplied to an owner or concrete finishing contractor. In commercial construction, the ready mixed concrete producer is not a

Sample Contract Provisions

Pumps. Install pumps as required to reroute the stream around the construction site and dewater foundations. When failure of a pump would result in movement of sediment or turbidity beyond the work area, a back-up pump shall be readily available. Bypass Pump. When SHOWN ON THE DRAWINGS, supply and

Sample Subcontract Agreement

: When Contractor orders in writing, Subcontractor, without nullifying this Agreement, shall make any and all changes in Subcontract Work, which are within the general scope of this Agreement.

TERMS AND CONDITIONS WHICH APPLY TO THE SUPPLY OF …

Terms and Conditions: Concrete Products 4 June 2018 1 TERMS AND CONDITIONS WHICH APPLY TO THE SUPPLY OF CONCRETE PRODUCTS BY ANY MEMBER OF THE BREEDON GROUP Please in particular note Clause 3.6 (Additional Charges) and Clause 10 (Limitation of Liability) 1. DEFINITIONS AND INTERPRETATION 1.1 In these Conditions

Guidelines for Concrete Mix Designs

Association (PCA) publication Design and Control of Concrete Mixtures is also a useful reference. II. Process At the start of the construction administration phase, it is a good idea to discuss the schedule for submission of concrete mix designs with the contractor in order to convey to him or her the

Guidance on Safety in Concrete Pumping

Standards and enforcement policy for construction concrete

Standards and enforcement policy for construction concrete

May 02, 2013 · Section 1926.702(e)(1) (Concrete pumping systems) requires that "Concrete pumping systems using discharge pipes shall be provided with pipe supports designed for 100 percent overload." Many other OSHA standards impose additional requirements for safely using concrete boom pump trucks to place concrete in construction, including the following sections

C-8 - Concrete Contractor

Mobile concrete pump with 42 metre boom and over. Self-erecting cranes 15 ton capacity and over. Carry Deck cranes 15 ton capacity and over.The wage rate for engineers operating mobile concrete pumps 52 metre boom and over shall be $2.00 per hour above the applicable rate. EFFECTIVE DATE 1.2 b) Pitman type cranes of 10 ton to less than 15 ton capacity.

SAFETY PROCEDURES - American Concrete Pumping …

A concrete pump can supply much more pressure than air. The compressed air will only continue to be compressed and store very dangerous levels of energy and could eventually explode and cause severe injury to anyone in the area. If air has been introduced into the boom and the concrete was .

SCOPE OF WORK CONCRETE PUMP, PLACE & FINISH …

CONCRETE PUMP, PLACE & FINISH EMERALD HEIGHTS 1.1 GENERAL A. WORK The term "Work" includes all labor, materials, equipment and services required of the CONTRACTOR, as shown, described or inferred in the Contract Documents. The CONTRACTOR is only to use its own forces and/or OWNER/CONSTRUCTION MANAGER approved sub-trades to undertake the

Construction Contracts in Georgia: Interpretation of

Pioneer Concrete Pumping Service, Inc. v. T&B Scottdale Contractors, Inc., 218 Ga. App. 596 (1995). Construction contracts typically are in writing, and most are long and complicated. Construction contracts not only describe the work to be performed and the materials to be used, but they also allocate among the parties the risks inherent in

BUILDING CONTRACT AGREEMENT

SAMPLE. Fixed Price + (Labour Only) Building Contract *Or the date referred to in clause 9.1, whichever is the later **Subject to clause 9.5 . The Builder is responsible for providing carpentry and related services to the Owner on a labour only basis in connection with the Pump fill concrete blocks as required.

Limitation of Liability Clause [Every Business Must Have it]

May 07, 2021 · Clauses must be written in a clear and unambiguous manner, placed in a conspicuous location within a contractual agreement, and unmistakeable in expressing intentions of either party. With a well-written and clear limitation of liability clause, you can immediately benefit your company's legal and financial interests.

AS 2550.15-1994 Cranes-Safe use - Concrete placing equipment

the safe use of concrete placing equipment and is intended for use in conjunction with AS 2550.1, Cranes—Safe use, Part 1: General requirements. This Part 15 of Cranes—Safe use, specifies the requirements which apply to concrete pumping equipment. Additional requirements are to be covered by subsequent parts. Published Standards in the

Master Drilling Agreement - SEC

Exhibit 10.1 . MASTER DRILLING AGREEMENT . THIS MASTER DRILLING AGREEMENT (this "Agreement") is made and entered into to be effective as of the 1st day of January 2013, by and between DIAMONDBACK E&P LLC ("Operator") and BISON DRILLING AND FIELD SERVICES LLC ("Contractor"). RECITALS: . A. Contractor is the owner of certain drilling rigs located in the Permian Basin (referred to …

SECTION-7: BILL OF QUANTITIES - gshp2.gov.in

and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, disposal of unserviceable as well serviceable material with all leads and lifts beyond the ROW complete as per technical specification clause 202.

CONSTRUCTION OF WATER BOOSTER PUMPING STATIONS

booster pumping stations. The main items of work to be constructed include, but are not limited to the following:- (a) Excavation for all structures and pipework. (b) Construction of concrete pump pit. (c) Manufacture and installation of aluminium pump pit covers.